CBBQW - ATL AIR TOOL LUBRICANT, ATL004

  • MSDS: CBBQW
  • Manufacturer: COILHOSE PNEUMATICS
  • Product Name: ATL AIR TOOL LUBRICANT, ATL004
  • National Stock Number: 9150-00N028119
Product Identification

Product ID:ATL AIR TOOL LUBRICANT, ATL004
MSDS Date:09/15/1993
FSC:9150
NIIN:00N028119
MSDS Number: CBBQW

Responsible Party
COILHOSE PNEUMATICS
200 CLAY AVE
MIDDLESEX, NJ 08846
US

Emergency Phone: 908-752-5000

Info Phone: 908-752-5000

Preparer: AUGUST PAPANIA

Cage: 58277

Contractor
COILHOSE PNEUMATICS
MIDDLESEX, NJ 08846 US

Telephone: 908-752-5000

Cage: 58277

Ingredients

OIL MIST, REMOVE FROM FURTHER EXPOS UNTIL

RTECS: 9999999ZZ


VOMITING. CALL MD IMMEDIATELY.

RTECS: 9999999ZZ


TO CLEAN SINCE RESIDUE IS DFCLT TO REMOVE.

RTECS: 9999999ZZ


& RETURNED TO DRUM RECONDITIONER. ALL OTHER CNTNRS

RTECS: 9999999ZZ


I/A/W GOVT REGS. FOR WORK ON TANKS REFER TO OSHA

RTECS: 9999999ZZ


PERTAINING TO CLEANING, REPAIRING, WELDING OR OTHER

RTECS: 9999999ZZ


HOOD FACE VELOCITY FOR CONFINED SPACES. PROVIDE VENT

RTECS: 9999999ZZ


EXPLOSIVE CONCENTRATIONS OF VAPOR IN AIR.

RTECS: 9999999ZZ


OIL-SOAKED. CLEANSE SKIN THORO AFTER CONT,

RTECS: 9999999ZZ


READILY REMOVED FROM SKIN BY WATERLESS HAND CLEANERS

RTECS: 9999999ZZ


SPECIALISTS.

RTECS: 9999999ZZ


SEVERELY HYDROTREATED PETROLEUM HYDROCARBON BASE STOCK;

CAS: 64742-58-1

OSHA PEL N/K

ACGIH TLV: 5 MG/M3 (MFR)


SOLVENT DEWAXED RESIDUAL OIL (PETROLEUM); (PETROLEUM-BASED

CAS: 64742-62-7

OSHA PEL N/K

ACGIH TLV: 5 MG/M3 (MFR)


EXTING FIRES INVOLVING THIS TYPE OF PROD,

RTECS: 9999999ZZ


RELATED TO SITUATION. PLAN FIRE PROT & RESPONSE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:HLTH STUDIES HAVE SHOWN THAT MANY
PETRO HYDROCARBONS & SYNTHETIC LUBRICANTS POSE POTNTL HUMAN HLTH
RISKS WHICH VARY FROM PERS TO PERS. AS PREC, EXPOS TO LIQS, VAPS,
MISTS/FUMES SHOULD BE MINIMIZED. PR LNG/RPTD SKIN CONT W/THIS PROD
TENDS TOREMOVE SKIN OILS POSS LEADING TO IRRIT & DERM; HOWEVER,
BASED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:ON HUMAN EXPER & AVAIL TOX DATA, THIS
PROD IS JUDGED TO BE NEITHER "CORR" NOR "IRRIT" BY OSHA. PROD
CONTACTING EYE MAY CAUSE IRRIT. PROD HAS LOW ORDER OF ORAL & DERMAL
TOX. POSS ASPIR HAZ. IN DUCED VOMIT MAY CAUSE ASPIR OF PROD INTO
LUNGS.
Medical Cond Aggravated by Exposure:UNKNOWN.

First Aid

First Aid:EYES:FLUSH W/CLEAR WATER FOR AT LST 15 MINS/UNTIL IRRIT
SUBSIDES. IF IRRIT PERSISTS, CALL MD. SKIN:REMOVE CONTAM CLTHG &
WASH SKIN THORO W/SOAP & WATER. INHAL:VAP PRESS IS VERY LOW. VAP
INHAL UNDER AM BIENT CNDTNS IS NORMALLY NOT PROB. IF OVERCOME BY
VAP FROM HOT PROD, IMMED REMOVE FROM EXPOS & CALL MD. IF BRTHG IS
IRREG/HAS STOPPED, START RESUSCITATION; ADMIN OXYG IF AVAIL. IF
OVEREXP TO (ING 6)

Fire Fighting

Flash Point Method:COC
Flash Point:365F,185C
Lower Limits:1%
Upper Limits:6%
Extinguishing Media:FOAM, WATER SPRAY (FOG), DRY CHEM, CARBON DIOXIDE &
VAPORIZING LIQ TYPE EXTING AGENTS MAY ALL BE SUITABLE FOR (ING 3)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER/FOAM MAY CAUSE FROTHING. USE WATER TO KEEP FIRE-EXPOS CNTNRS
COOL. WATER FROTH MAY BE USED TO(SUPDAT)

Accidental Release

Spill Release Procedures:KEEP PROD OUT OF SEWERS & WATERCOURSES BY
DIKING/IMPOUNDING. ABSORB W/SAND OR INERT MATL. SWEEP/SCOOP UP &
REMOVE. PVNT SPREAD OF SPILL. ADVISE AUTHS IF PROD HAS ENTERED/MAY
ENTER SEWERS, WATERCOURSES /EXTENSIVE LAND AREAS. ASSURE COMFORMITY
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CNTNRS CLSD WHEN NOT IN USE. DO
NOT HANDLE NEAR HEAT, SPKS, FLAME/STRONG OXIDANTS. MIN BRTHG VAP,
MIST/FUMES. AVOID PRLNG/RPTD CONT W/SKIN.
Other Precautions:EMPTY CNTNRS RETAIN RESIDUE(LIQ/VAP) & CAN BE
DANGEROUS. DO NOT PRESSURIZE, WELD, CUT, BRAZE, SOLDER, DRILL,
GRIND/EXPOSE SUCH CNTNRS TO HEAT, FLAME, SPKS/OTHER SOURCES OF
IGNIT; THEY MAY EXPLODE & CA USE INJURY/DEATH. DO NOT ATTEMPT (ING
8)

Exposure Controls

Respiratory Protection:USE ONLY NIOSH/MSHA APPRVD EQUIP. NORMALLY NOT
NEEDED AT AMBIENT TEMPS. USE SUPPLIED AIR RESP PROT IN
CONFINED/ENCLSD SPACES, IF NEEDED. USE FILTER, DUST, FUME/MIST RESP
TYPE UNDER MISTING CNDTNS. USE CAN/CARTRIDGE; GAS/VAP RESP (SUPP
DATA)
Ventilation:ALWAYS MAINTAIN BELOW PELS. USE LOC EXHST TO CAPTURE VAP,
MIST/FUMES, IF NEC. PROVIDE GREATER THAN 6O FT PER MIN(ING 12)
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . USE CHEM-RESIST APRON/OTHER
IMPERVIOUS(SUPDAT)
Work Hygienic Practices:REMOVE CONTAM CLTHG; LAUNDER/DRY-CLEAN BEFORE
REUSE. REMOVE CONTAM SHOES & THORO CLEAN BEFORE REUSE; DISCARD IF
(ING 14)
Supplemental Safety and Health
FIRE FIGHT PROC:FLUSH SPILLS AWAY FROM EXPOS. MIN BRTHG GASES, VAP,
FUMES/DECOMP PRODS. SPILL PROC:W/LOC REGS. RESP PROT:TYPE UNDER
CNDTNS EXCEEDING TWA STD. OTHER PROT EQUIP:CLTHG, IF NEEDED, TO
AVOI D CONTAM REGULAR CLTHG WHICH COULD RSLTIN PRLNG/RPTD SKIN
CONTACT.

Chemical Properties

Boiling Pt:B.P. Text:WIDE RANGE
Vapor Pres:<0.1 @ 38C
Vapor Density:>8
Spec Gravity:<1 (H*2O=1)
Evaporation Rate & Reference:<1 (N-BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:AMBER LIQUID; PETROLEUM ODOR.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDANTS SUCH AS LIQUID CHLORINE, CONCENTRATED
OXYG, SODIUM HYPOCHLORITE OR CALCIUM HYPOCHLORITE.
Stability Condition to Avoid:OPEN FLAMES. PRODUCT IS STABLE & WILL NOT
REACT VIOLENTY W/WATER.
Hazardous Decomposition Products:FUMES, SMOKE, CARBON MONOXIDE, OXIDES
OF SULFUR & OTHER DECOMPOSITION PRODS, IN CASE OF INCOMPLETE
COMBUSTION.

Disposal

Waste Disposal Methods:CONSULT FEDERAL, STATE OR LOCAL AUTHORITIES FOR
PROPER DISPOSAL PROCEDURES. ASSURE COMFORMITY W/APPLICABLE DISPOSAL
REGULATIONS. DISPOSE OF ABSORBED MATERIAL AT AN APPROVED WASTE SITE
OR FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.